Researchers at the University of Southern California (USC) have developed an artificial intelligence framework that could make obstructive sleep apnea assessment faster and more accessible. The system analyses just 10 minutes of physiological data to detect the disorder and estimate its severity, potentially reducing the amount of recorded data required for reliable assessment.
Known as Long-Range Interdependencies Aware analysis (LRIA), the framework identifies relationships between respiratory and cardiovascular signals that conventional AI models may fail to capture. It was evaluated across five datasets involving more than 35,000 participants and consistently outperformed several existing models.
The findings were published in Nature Communications. The study was led by researchers from USC’s Ming Hsieh Department of Electrical and Computer Engineering, including senior author Paul Bogdan, in collaboration with an international team of engineers, physicians and sleep researchers.
How the AI Framework Analyses Sleep Apnea
Obstructive sleep apnea is a chronic condition in which breathing repeatedly stops or becomes restricted during sleep. These interruptions can lower blood oxygen levels and are associated with a higher risk of cardiovascular disease, metabolic disorders and other health complications.
The standard diagnostic method is overnight polysomnography, which monitors breathing, blood oxygen, heart activity and other physiological signals. While it provides detailed information, the procedure can be expensive, labour-intensive and difficult for some patients to access.
Many existing AI systems focus on individual moments or short-term patterns in physiological recordings. LRIA takes a different approach by examining how different bodily processes interact over longer periods.
The framework uses fractional dynamic modelling to convert physiological signals into coupling matrices. These representations capture relationships between airflow, blood oxygen, heart rate and respiratory effort. The resulting data is then processed through a deep-learning model to classify sleep apnea into four categories: normal, mild, moderate and severe.
The researchers found that these coupling representations became stable after approximately 10 minutes of recorded data. This indicates that shorter recording periods may contain sufficient information for the framework to identify physiological patterns associated with the disorder.
Tested Across Five Datasets
To assess its accuracy and ability to work across different populations, the research team tested LRIA using five cohorts with varying demographic profiles, clinical settings and recording methods. These included the Sleep Heart Health Study, the Multi-Ethnic Study of Atherosclerosis, the Osteoporotic Fractures in Men Sleep Study, a Massachusetts General Hospital dataset and a clinical cohort from western Romania.
For binary sleep apnea detection, the framework recorded area-under-the-receiver-operating-characteristic-curve (AUROC) scores of 0.947 in the Sleep Heart Health Study, 0.942 in the Multi-Ethnic Study of Atherosclerosis, 0.920 in the Osteoporotic Fractures in Men cohort and 0.918 in the Massachusetts General Hospital cohort.
Across the datasets, LRIA achieved AUROC values above 0.91 and performed between 8% and 18% better than state-of-the-art comparison models. Its performance remained consistent despite differences in the populations and data-collection environments.
The researchers also compared the framework with established deep-learning architectures and a recent sleep-analysis model. LRIA produced stronger results while working with a condensed representation of the original physiological recordings.
Potential for More Accessible Sleep Assessment
The researchers see LRIA as a possible foundation for automated tools that could support sleep apnea screening and clinical decision-making. Since it uses physiological signals commonly collected during laboratory and ambulatory sleep studies, the approach may eventually be adapted for less burdensome assessment systems.
However, the framework is not intended to replace physician judgment or overnight polysomnography at this stage. The study relied on retrospective analysis of previously collected sleep recordings. Prospective clinical studies will be necessary to establish how reliably the technology performs in real-world healthcare settings.
The researchers also noted that the study did not include sex-stratified analyses, as its primary focus was evaluating the framework rather than investigating differences in disease mechanisms across patient groups.
Despite these limitations, the findings demonstrate how mathematical modelling and AI can help identify complex relationships within physiological data. By extracting useful information from shorter recordings, LRIA could eventually contribute to faster sleep data analysis, wider screening opportunities and more personalised assessment of sleep-disordered breathing.